User Manual
E727T0005, valid for E-727
BRO, 2019-06-28
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 106 / 240
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Ramp Curves
WAV command Comments Waveform Segment
WAV 4 X RAMP 2000 20 10 2000 0 300 1000
<WaveTableID> = 4
<AppendWave> = X
<WaveType> = RAMP
<SegLength> = 2000
<Amp> = 20
<Offset> = 10
<WaveLength> = 2000
<StartPoint> = 0
<SpeedUpDown> = 300
<CurveCenterPoint> = 1000
The previous contents
of the wave table are
overwritten by the
new segment,
waveform offset = 10
(Do not confuse with
the wave generator
output offset set with
WOS!)
symmetric curve
WAV 4 X RAMP 2000 35 0 2000 499 300 1000
<WaveTableID> = 4
<AppendWave> = X
<WaveType> = RAMP
<SegLength> = 2000
<Amp> = 35
<Offset> = 0
<WaveLength> = 2000
<StartPoint> = 499
<SpeedUpDown> = 300
<CurveCenterPoint> = 1000
The previous contents
of the wave table are
overwritten by the
new segment,
symmetric curve
WAV 5 X RAMP 2000 15 0 1800 120 150 900
<WaveTableID> = 5
<AppendWave> = X
<WaveType> = RAMP
<SegLength> = 2000
<Amp> = 15
<Offset> = 0
<WaveLength> = 1800
<StartPoint> = 120
<SpeedUpDown> = 150
<CurveCenterPoint> = 900
The previous contents
of the wave table are
overwritten by the
new segment,
symmetric curve