HUNTER-PRO Series Installation Guide 57
Par. Description Setting to ‘+’ means…
P Pre Alarm Report The system reports when entry delay starts
O Tst Rprt in OFF Test reports are sent when the system is disarmed
S Split Account No. When reporting to 2 MSs (with different account numbers),
account #1 will be reported to MS1 and #2 to MS2.
Assigning account number per partition is disabled.
D Disarm after Al. The system will report a zone open event that occurs
immediately after alarm, even when the open/close
parameter is disabled (in MS1 options menu).
5.5.4.1 Number of Rings
No. of Rings 10
Set the number of rings before the system picks up an incoming call. To manually
answer, enter Master code and press [ENTR] twice. Press [ENTR]
5.5.4.2 ACK Waiting Time
Ack Wait Time:
PSTN:20 GSM:30
Set ACK time (the time in seconds in which the panel waits for MS handshake signal).
If no ACK is received, a communication error is displayed. HUNTER-PRO series allows
different waiting times for PSTN and GSM modules. The max. waiting time for both is
60 sec. Press [ENTR]
5.5.4.3 External Line
External Line
_
Set a dial-up access number (up to 2 digits). Press [ENTR]
5.5.4.4 Number of Transmissions
No. of Trans.: 5
Set the number of the long-range radio re-transmissions. The interval between the
transmissions is 10 seconds. Press [ENTR]