SG/SSHSeriesServiceManual 15
5. Turn on the main gas supply line.
6. Check the supply gas pressure with the
manometer and compare the reading to the
supply gas pressure table to determine what the
incoming gas pressure should be.
SupplyPressureTable
NAT LP
7 to 9 11 to 13
NOTE: You cannot adjust the supply gas
pressure at the unit. Anything
over/under the recommended
amount should be adjusted at the
facility’s main gas line.
7. Shut off the main gas supply line.
8. Disconnect the manometer.
9. Remove the test fitting.
10. Apply Teflon paste to gas supply plug.
11. Reinstall gas supply plug with a 3/16 inch hex
wrench.
12. Turn on the main gas supply line.