PitcoSolsticeandSolsticeSupremeHighEfficiencyGasFryers
SG/SSHSeriesServiceManual 53
AdjustingManifoldGasPressure
1. Check the manifold gas pressure with the
manometer and compare the reading to the
Manifold Gas Pressure table.
ManifoldGasPressureTable
NAT LP
4.0” 10”
2. Insert a flathead screwdriver into the cap and
turn counter-clockwise to remove it.
3. Insert flathead screwdriver into cap and turn
counter-clockwise to increase the gas pressure or
clockwise to decrease the gas pressure.
4. When adjustment is complete:
a. Shut off the gas supply line.
b. Disconnect manometer.
c. Remove the test fitting.
d. Reinstall the gas manifold plug.
e. Turn on gas supply line.