PitcoSolsticeandSolsticeSupremeHighEfficiencyGasFryers
SG/SSHSeriesServiceManual 61
ReplacingtheFlushHoseAssemblyandValve
1. Remove the lower connection at the 3-way
return valve in the back of the unit using a
15/16 inch wrench.
2. Remove the male quick disconnect using a
15/16 inch wrench.
3. Unplug the proximity switch.
4. Remove two (2) screws holding the flush hose
assembly using a 5/16 socket.
5. Remove the flush hose assembly.
6. Remove the four (4) screws from the magnets
using a flathead screwdriver.