EasyManua.ls Logo

Pitco SSH Series - Pitco Hi-Limit Thermostat Replacement

Pitco SSH Series
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PitcoSolsticeandSolsticeSupremeHighEfficiencyGasFryers
SG/SSHSeriesServiceManual 58
ReplacingtheHiLimitThermostat
1. Remove the two (2) bolt clamp screws on the hi-
limit probes using a Phillips screwdriver.
2. Remove the two (2) screws, which hold the
high-limit thermostat, using a Phillips
screwdriver.
3. Remove the two (2) screws, which hold the
wires, using a flathead screwdriver.
4. Replace the high-limit thermostat by following
steps 1 through 3 in reverse.

Table of Contents

Related product manuals