PitcoSolsticeandSolsticeSupremeHighEfficiencyGasFryers
SG/SSHSeriesServiceManual 79
SolidStateThermostatFieldCalibration
If field calibration is necessary, follow these steps:
Allow appliance to heat to set point, and allow 30 minutes to stabilize.
Measure the vat center oil temperature. Compare this with the knob pointer scale.
To reposition the knob, pry off the cap of the knob with a sharp knife blade.
Without turning the shaft, loosen the 5/16-compression nut and pull the knob off.
Re-install the knob with the pointer at the temperature indicated on the test thermometer.
Tighten the 5/16-compression nut, and install cap.