PitcoSolsticeandSolsticeSupremeHighEfficiencyGasFryers
SG/SSHSeriesServiceManual 30
ReplacingtheSelfCleaningBurnerSolenoid
1. Remove the SCB flex tube fitting using a
1/2 inch open-ended wrench.
2. Remove the SCB valve inlet fitting using a
1/2 inch open-ended wrench.
3. Disconnect the terminals using needle-nose
pliers.
4. Remove the two (2) elbows using a 1/2 inch
open-ended wrench.
5. Follow steps 1 through 4 in reverse to reinstall
SCB valve.