Page #60 background imageLoading...
Page #60 background image
PitcoSolsticeandSolsticeSupremeHighEfficiencyGasFryers
SG/SSHSeriesServiceManual 60
ReplacingtheReturnValve
IMPORTANT: Oil must be removed from the tank before replacing the return valve.
1. Remove all connections from the 3-way return
valve using a 1/16 inch wrench.
2. Remove the cotter pin on return valve using
needle-nose pliers.
3. Replace the return valve by following steps 1
through 2 in reverse, replacing the cotter pin if
necessary.
NOTE: Thread sealant is not required for
these fittings.