Bookletmaker SR 85 February 2001PAGE
EDI 7.5 Test points
7.5.1
PURPOSE
The purpose of the Test points (see location on page 7.4.1, TP 1-16) is to use them as the
(+) connector when adjusting sensors or when checking the function of some components
and there wires. Use any common ground as (-) connector.
Voltage when low: Less than 0.9 VDC
Voltage when high: Greater than 2.2 VDC
Measured value
Test point Description after switched on
TP 1 Saddle stapling sensor SEN 1 Low inactivated
TP 2 Fold stop sensor SEN 2 High inactivated
TP 3 Home position side registration High inactivated
TP 4 Fold knife home position switch SW 2 Low activated
TP 5 Stapler home position switch SW 1 Low activated
TP 6 Jam signal from Trimmer High inactivated
TP 7 Edge stapling sensor SEN 3 High inactivated
TP 8 Outfeed sensor SEN 4 Low inactivated
TP 9 Infeed sensor SEN 5 High inactivated
TP 10 Trimmer knife activated High inactivated
TP 11 Length adjustment maximum limit switch SW 3 High inactivated
TP 12 Not used
TP 13 Length adjustment minimum limit switch SW 4 High inactivated
TP 14 Trimmer connected High inactivated
TP 15 Rear staple detection High inactivated
TP 16 Front staple detection High inactivated