SD700
CONFIGURATION REGISTER
91
PARAMETERS
FACTORY SETTINGS
SETTING 1
SETTING 2
9 SPD HI1=+100%
SPD HIG RNG AIN1
+100%
___________________
___________________
10 FB1 = +0.0l/s
+0.0l/s
___________________
___________________
11 FB1-SP = 0%
0%
___________________
___________________
12 FA1 = +10.0l/s
+10.0l/s
___________________
___________________
13 FA1-SP = 100%
100%
___________________
___________________
14 AIN1 LOSS=N
N
___________________
___________________
15 1_Z BAND=OFF
AIN1 ZERO BAND
OFF
___________________
___________________
16 FILTER1=OFF
AIN1 STABIL FILT
OFF
___________________
___________________
G4 Inputs S4.3: Analogue Input 2
1 SENSOR 2 ?=N
N
___________________
___________________
2 SENSOR 2=Bar
Bar
___________________
___________________
3 AIN2 FORMAT=mA
mA
___________________
___________________
4 INmin2=+4mA
AIN2 LOW RANGE
+4mA
___________________
___________________
5 Smi2=+0.0Bar
SENS2 LOW RANGE
+0.0Bar
___________________
___________________
6 INmax2=+20mA
AIN2 HIGH RANGE
+20mA
___________________
___________________
7 Sma2=+10.0Bar
SENS2 HIGH RANGE
+10.0Bar
___________________
___________________
8 SPD LO2=+0%
SPD LO RNG AIN2
+0%
___________________
___________________
9 SPD HI2=+100%
SPD HIG RNG AIN2
+100%
___________________
___________________
10 FB2 = +0.0Bar
+0.0Bar
___________________
___________________
11 FB2-SP = 0%
0%
___________________
___________________
12 FA2 = +10.0Bar
+10.0Bar
___________________
___________________
13 FA2-SP = 100%
100%
___________________
___________________
14 AIN2 LOSS=N
N
___________________
___________________
15 2_Z BAND=OFF
AIN2 ZERO BAND
OFF
___________________
___________________
16 FILTER2=OFF
AIN2 STABIL FILT
OFF
___________________
___________________
G4: Inputs S4.4: Pulse Input
1 Sensr U=l/m
l/m
___________________
___________________
2 Pls/s = 100 l/s
LIQU AMOUNT/PULS
100l/s
___________________
___________________
3 M Rn=1000 l/s
FLOW MAX RANGE
1000l/s
___________________
___________________
G4: Inputs S4.6: Optic Fiber
1 FIBER MODE = MAS
MAS
___________________
___________________
3.5 CONTROL = NONE
NONE
___________________
___________________
3.6 FAULT = N
N
___________________
___________________
3.7 SPIN STP = N
N
___________________
___________________
6.5 T/O F.O = 0
0
___________________
___________________

Table of Contents

Other manuals for Power Electronics SD700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Power Electronics SD700 Series and is the answer not in the manual?

Power Electronics SD700 Series Specifications

General IconGeneral
BrandPower Electronics
ModelSD700 Series
CategoryInverter
LanguageEnglish

Related product manuals