Chapter 4: Technology Background
85
RAID 0
A RAID 0 source logical drive can migrate to the following target logical drives:
See “Migrating a Logical Drive” on page 65.
RAID 1
A RAID 1 Source logical drive can migrate to the following Target logical drives:
See “Migrating a Logical Drive” on page 65.
Target Requirements
RAID 0 Add physical drives.
RAID 1 2 physical drives only.
Only a single-drive RAID 0 can migrate to RAID 1 by adding 1
physical drive.
RAID 1E 3 or more physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 5 3 physical drives minimum, maximum 4 (R4) or 6 (R6).
RAID 0 must have less than 4 (R4) or 6 (R6) physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 6 4 physical drives minimum, 4 (R4) or 6 (R6).
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 10 4 physical drives minimum. Even number of physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
Target Requirements
RAID 0 None.
RAID 1E 3 or more physical drives.
Add 1 or more physical drives.
RAID 5 3 physical drives minimum, 4 (R4) or 6 (R6).
RAID 1 must have less than 4 (R4) or 6 (R6) physical drives.
Add 1 or more physical drives.
RAID 10 4 physical drives minimum. Even number of physical drives.
Add 2 or more physical drives.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology Pegasus R6 and is the answer not in the manual?

Promise Technology Pegasus R6 Specifications

General IconGeneral
BrandPromise Technology
ModelPegasus R6
CategoryStorage
LanguageEnglish

Related product manuals