CHAPTER TITLE QUANTA SMASH
4-11
BMC Information
The BMC level commands provide several options to configure
and display parameters of the management agent.
Displays information for the board
show /SP
Reset BMC
reset /SP
Set server identify LED to be off
set /SP ServerIdentify=off
Set server identify LED to be on
set /SP ServerIdentify=on
Set server identify LED to be blinking
set /SP ServerIdentify=blinking
/SP
Table 4-9: Targets and Verbs
R
ELATED TARGETS SUPPORTED VERBS
cd exit help create delete set show reset start stop version
/vvv v v
/SP v v v v v v v
Table 4-10: /SYS/fan
P
ROPERTY NAME VALID VALUE ACCESS DESCRIPTION
BMCVersion R
Display BMC firmware
revision
BMCGUID R Display BMC GUID
ServerIdentify
off
on
blinking
R/W
Configuring server
identify LED
BMCMAC R
Display the NIC physical
address used by server
management agent