EasyManuals Logo

Radwin 5000 Installation Guide

Radwin 5000
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #108 background imageLoading...
Page #108 background image
RADWIN 5000 Installaon Guide
August 2023
108
Table 11: Frequency Bands 5250‐5350 MHz and 5470‐5725 MHz
Cat. No.
Type
Gain (dBi)
Dir
BW
Tx Power per
chain (dBm)
Min. Safe
Distance (cm)
Integrated
Flat DP BS
11.0
120°
16
20
RW‐9061‐5004
Flat DP BS
11.0
120°
16
20
Integrated
Flat DP BS
12.0
95°
15
20
Integrated
Flat DP BS
13.0
90°
14
20
RW‐9061‐5001
Flat DP BS
14.0
90°
13
20
RW‐9061‐5002
Flat DP BS
15.5
60°
11.5
20
Integrated
Flat DP
16.0
35°
11
20
Integrated
Flat DP
16.5
35°
10.5
20
RW‐9613‐4960
Flat DP
23.0
4
20
Integrated
Flat DP
23.5
3.5
20
RW‐9622‐5001
Flat DP
29.0
‐2
20
RW‐9401‐5002
Shark Fin SP
12.5
50°
14.5
20
RW‐9721‐5158
Dish DP
28.0
5.5°
‐1
20
RW‐9732‐4958
Dish DP
32.0
‐5
20
Table 12: Frequency Bands 5150‐5250 MHz
Cat. No.
Type
Gain (dBi)
Dir
BW
Tx Power per
chain (dBm)
Min. Safe
Distance (cm)
Integrated
Flat DP BS
11.0
120°
22
20
RW‐9061‐5004
Flat DP BS
11.0
120°
22
20
Integrated
Flat DP BS
12.0
95°
21
20
Integrated
Flat DP BS
13.0
90°
18
20
RW‐9061‐5001
Flat DP BS
14.0
90°
18
20
RW‐9061‐5002
Flat DP BS
15.5
60°
18
20

Table of Contents

Other manuals for Radwin 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin 5000 and is the answer not in the manual?

Radwin 5000 Specifications

General IconGeneral
Channel Bandwidth5 MHz, 10 MHz, 20 MHz, 40 MHz
EncryptionAES
Product TypePoint-to-Point
InterfaceEthernet
Frequency Bands5.1 GHz, 5.4 GHz, 5.8 GHz
ModulationAdaptive Modulation (QPSK to 256QAM)

Related product manuals