RADWIN 5000 Installaon Guide
August 2023
75
Figure 96: Input port: SU PRO/AIR EMB unit
Connecon label: None
2. Route the CAT‐5e and ground cables down from the radio to a PoE.
3. Recommended, although not required: route the CAT‐5e cable via 2 LPUs: one near the radio, one near
the PoE.
4. Connect ground cable to ground.
5. Perform nal connecons via the SU PRO/AIR EMB PoE.
2.14.6 Power Supplies
RADWIN 5000 radio units use a Power‐over‐Ethernet (PoE) source to supply both power and ethernet
connecvity.
The devices used for this can be PoE devices, the IDU‐H, or the IDU‐S. Which device you use to supply
power to the radio unit depends on your system’s condions.
These devices are briey described in this secon.

Table of Contents

Other manuals for Radwin 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin 5000 and is the answer not in the manual?

Radwin 5000 Specifications

General IconGeneral
Channel Bandwidth5 MHz, 10 MHz, 20 MHz, 40 MHz
EncryptionAES
Product TypePoint-to-Point
InterfaceEthernet
Frequency Bands5.1 GHz, 5.4 GHz, 5.8 GHz
ModulationAdaptive Modulation (QPSK to 256QAM)