The equipment will operate only in the frequency bands 5470 ‐ 5725 MHz and 5725 ‐ 5850
MHz. The soware version to be sold in Brazil with blocking is from version 4.6. The power supplies
presented in this user manual are not sold with this product.
O equipamento irá operar apenas nas faixas de frequências 5470 ‐ 5725 MHz e 5725 ‐ 5850 MHz. A versão
do soware a ser comercializado no Brasil com bloqueio é a parr da versão 4.6.
As fontes de alimentação apresentadas neste manual não serão comercizliadas junto com este produto.
Equipment connected to the protecve earthing of the building installaon through the mains connecon
or through other equipment with a connecon to protecve earthing ‐ and to a cable distribuon system
using coaxial cable, may in some circumstances create a re hazard. Connecon to a cable distribuon
system has therefore to be provided through a device providing electrical isolaon below a certain
frequency range (galvanic isolator, see EN 60728‐11).
Norway
Utstyr som er koplet l beskyelsesjord via neplugg og/eller via annet jordlkoplet utstyr ‐ og er lkoplet
et kabel‐TV ne, kan forårsake brannfare. For å unngå dee skal det ved lkopling av utstyret l kabel‐TV
neet installeres en galvanisk isolator mellom utstyret og kabel‐ TV neet
Sweden
Utrustning som är kopplad ll skyddsjord via jordat vägguag och/eller via annan utrustning och samdigt
är kopplad ll kabel‐TV nät kan i vissa fall medföra risk för brand. För a undvika dea skall vid anslutning
av utrustningen ll kabel‐TV ät gal‐ vanisk isolator nnas mellan utrustningen och kabel‐TV nätet.
In countries where the radio is not regulated the equipment can be operated in any regulaon
conguraon, best results will be obtained using Universal regulaon conguraon.
Applicable requirements of Naonal Electrical Code (NEC), NFPA 70; and the Naonal Electrical Safety Code,
ANSI/IEEE C2, must be considered during installaon.
NOTES:
1. A Primary Protector is not required to protect the exposed wiring as long as the exposed wiring length is
limited to less than or equal to 140 feet, and instrucons are provided to avoid exposure of wiring to
accidental contact with lightning and power conductors in accordance with NEC Secons 725‐54 (c) and
800‐30.
In all other cases, an appropriate Listed Primary Protector must be provided. Refer to Arcles 800 and
810 of the NEC for details.
2. For protecon of ODU against direct lightning strikes, appropriate requirements of NFPA 780 should be
considered in addion to NEC.
3. For Canada, appropriate requirements of the CEC 22.1 including Secon 60 and addional requirements
of CAN/CSA‐B72 must be considered as applicable.