Gas
Edition 10-2008a
The burner blower creates a negative pressure inside the compensation hose, which governs the 1.
pressure regulation throttle.
The  nal adjustment of the heat load through the main throttle is achieved with the CO2.
2
screw.
Gas Valve
Compensation hose
CO
2
screw
Particle  lter Pressure regulation throttle Main throttle
Parallel operated gas solenoid vales
P-