141
Common Information
Edition 10-2008a
Intruction for manual descaling
Protective clothing and tools needed:
- Protective clothing:
Goggels, gloves, apron
- Container with descaler
- Foot pump (6004.0203)
1 SCC or CM shall only be descaled when the cabi-
net temperature is below 40°C (104°F)
Start cool down if needed.
2 Empty and re ll steam generator to cool it down.
Now empty steam generator again manually and
measure the amount of water draining from the
steam genrator.
3 Descaler shall ONLY be filled via the steam
inlet port inside the steam generator!
Remove hinged rack (trolley) and swing air baf e
open.
4 Insert hose of descaler pump into steam inlet port
inside interior cabinet.
Do NOT ll through level electrode opening!
Damage to other components may occur!
5 Place descaler can into cabinet.
6 Insert the other hose end into can. Make sure the
red rubber plug rmly sits in the can opening
2
3
4
5,6