P/N 016-0171-584 Rev. D 65
TROUBLESHOOTING
5200
.2 Nozzle indexing error
1. Check that all nozzle control valves are
connected to the boom harness.
2. Verify nozzle counts on left and right booms.
3. Check nozzle control valve diagnostics or
status LEDs to identify valve is causing error.
4. Restart the calibration wizard and complete
the nozzle indexing to properly set the nozzle
control valve locations across the implement.
5. Check the terminator cables for bare or worn
wires.
6. Check the CAN voltages on the boom cables.
7. Reload the object pool and disconnect power
to the machine.
.3 Nozzle indexing incomplete
1. Restart the calibration wizard and complete
the nozzle indexing to properly set the nozzle
control valve locations across the implement.
2. Cycle system power and reset defaults.
.16 Too many nozzles detected
1. Restart the calibration wizard and verify the
number of nozzle control valves connected to
the Hawkeye nozzle control system.
2. Cycle system power and reset defaults.
523008 .2
Nozzle calibration tip mismatch/
error
1. Select the appropriate tip type. Refer to the
Injection Pump Efficiency section on page 48
for additional assistance.
2. Restart the calibration wizard to reset the tip
type setting for the nozzle control system.
3. Cycle system power and reset defaults.
523009 .2
Nozzle calibration spacing
mismatch/error
1. Restart the calibration wizard to re-enter the
tip spacing measurement.
2. Cycle system power and reset defaults.
523010 .18
Some nozzles were not detected
during nozzle calibration
1. Check that all nozzle control valves are
connected to the boom harness.
2. Check the nozzle control valve diagnostics or
status LED.
3. Cycle system power and reset defaults.
4. Connect the Raven Service Tool to the
ISOBUS and verify communication to the
nozzles.
523088
.12 Nozzle memory error (single)
1. Restart the calibration wizard.
2. Cycle system power and reset defaults.
3. Contact a local Raven dealer for additional
assistance.
.31 Nozzle memory warning (single)
1. Restart the calibration wizard.
2. Cycle system power and reset defaults.
3. Contact a local Raven dealer for additional
assistance.
Code ID Description Recommended Actions