APPENDIX
C
P/N 016-0171-584 Rev. D 89
APPE NDIX C
CALIBRATION VALUES
SECTION WIDTHS
Use the following formulas to help calculate the section widths.
Calculate the section width with the formula:
Where T = the number of Tips in each section, S = the Spacing between tips, and SW = the Section Width.
FOR EXAMPLE:
20 tips in a section with spacing of 40 inches [50.8 cm] would yield:
or a Section Width of 800 inches [2032 cm] (approximately 67 feet [20 m]). Enter 800 [2032] as the width for
this section.
TARGET RATE CALIBRATION
The following information must be known in order to determine which spray nozzles to use with the sprayer:
Nominal Application Pressure_________ PSI [kpa]
Target Application Rate_________ GPA [lit/ha]
Target Speed_________ MPH [km/h]
Nozzle Spacing_________ inches [cm]
From this information, calculate the volume per minute per nozzle as follows:
NVPM = Nozzle Volume per Minute (gallons/acre [lit/ha]), Rate = Target Application Rate, Speed = Target Speed
of Application, and NS = Nozzle Spacing.
TS× SW=
20 40× 800=
NVPM
Rate Speed× NS×
5 940 60 000,[],
--------------------------------------------------
=