66 Hawkeye Nozzle Control Operation Manual
523089
.12 Nozzle memory error (single
1. Restart the calibration wizard.
2. Cycle system power and reset defaults.
3. Contact a local Raven dealer for additional
assistance.
.31
Nozzle memory warning
(multiple)
1. Restart the calibration wizard.
2. Cycle system power and reset defaults.
3. Contact a local Raven dealer for additional
assistance.
523090 .1 Nozzle calibration error (single)
1. Restart the calibration wizard to recalibrate
the nozzle control system.
2. Cycle system power and reset defaults.
523091 .1
Nozzle calibration error
(multiple)
1. Restart the calibration wizard to recalibrate
the nozzle control system.
2. Cycle system power and reset defaults.
523092 .31
No tip information entered for
nozzle control valve (single)
1. Select the appropriate tip type. Refer to
Injection Pump Efficiency section on page 48
for additional assistance.
2. Restart the calibration wizard to reset the tip
type setting for the nozzle control system.
523093 .31
No tip information entered for
nozzle control valves (multiple)
1. Restart the calibration wizard to configure tip
information for the Hawkeye nozzle control
valves.
523126 .13
Unable to detect Hawkeye ECU
orientation
1. Check the ECU mounting position and verify
the ECU is securely mounted.
2. Recalibrate the ECU gyro.
523136
.16
Monitored flow rate is higher
than the target rate deadband
1. Reduce the equipment speed.
2. Review “Avoiding Skips with Hawkeye™
Nozzle Control System” section on page 71.
3. Refer to the Hawkeye Upper Home Screen
section on page 46 for assistance with setting
or adjusting the target rate.
4. Refer to the System Settings Tab - Alarm
section on page 34 for assistance with setting
or adjusting the off rate percent.
.18
Monitored flow rate is lower than
the target rate deadband
1. Increase the equipment speed.
2. Refer to the Hawkeye Upper Home Screen
section on page 46 for assistance with setting
or adjusting the target rate.
3. Refer to the System Settings Tab - Alarm
section on page 34 for assistance with setting
or adjusting the off rate percent.
523137 .18 Minimum flow not met
1. Activate product pump.
2. Review “Avoiding Skips with Hawkeye™
Nozzle Control System” section on page 71.
3. Increase pump output to maintain the
minimum recommended flow rate for each
nozzle control valve.
Code ID Description Recommended Actions