ECODRIVE03-SGP-03VRS Description of Diagnostic Messages F… and E… 4-19
DOK-ECODR3-SGP-03VRS**-WA01-EN-P
Cause:
The emergency stop switch has been pressed.
Remedy:
Eliminate the malfunction that has caused the emergency switch to be
actuated, and clear the error.
See also the functional description: "Emergency stop feature".
F629 Positive travel limit exceeded
The drive has received a command value which has led to an axis
position outside the positive travel range. The axis has been brought to a
standstill with the error response "Set velocity command value to zero".
Bit 2 of paramater P-0-0090, Travel limit parameter is set for "Exceeding
travel range is an error", or after exceeding the position limit a drive
control command has been started (such as the drive-controlled homing
procedure).
Cause:
S-0-0049, Positive position limit value exceeded.
Remedy:
1. Check S-0-0049, Positive position limit value
2. Check the software limits of the control system
3. Activate the axis after the error response
Procedure:
• Clear the error.
• If the power supply was turned off, turn it back on.
• Move the axis into the permissible working range.
Note: Only command values which lead back into the allowed
working range will be accepted. With other command values,
the drive will stop again. - The parameter S-0-0057, Position
window defines a tolerance for the travel limits.
See also the functional description: "Travel Range Limits ".
F630 Negative travel limit exceeded
The drive has received a command value which has led to an axis
position outside the negative travel range. The axis has been brought to a
standstill with the error response "Set velocity command value to zero".
Bit 2 of paramater P-0-0090, Travel limit parameter is set for "Exceeding
travel range is an error", or after exceeding the position limit a drive
control command has been started (such as the drive-controlled homing
procedure).