5-10 Description of Diagnostic Messages B…; C…, D… and A ECODRIVE03-SGP-03VRS
DOK-ECODR3-SGP-03VRS**-WA01-EN-P
C211 Invalid feedback data (->S-0-0022)
Invalid data has been encountered when the parameters stored in the
motor feedback were read, or an error has occurred when the data was
read.
Causes:
1. Motor feedback cable not connected or defective
2. Motor feedback defective
3. Drive controller defective
Remedy for:
1. Check motor feedback cable; connect both sides
2. Replace motor
3. Replace amplifier
See also the functional description "S-0-0128, C200 Communication
phase 4 transition check".
C212 Invalid amplifier data (->S-0-0022)
During drive initialization, the operating software accesses data from an
EEPROM in the drive controller. This error message is generated if the
attempt to read the data has failed.
Causes:
Defective hardware in the drive controller.
Remedy:
Replace drive controller.
See also the functional description "S-0-0128, C200 Communication
phase 4 transition check".
C213 Position data scaling error
Cause:
The scaling parameters for position data permit the position data display
format to be selected. The drive-internal position data format depends on
the employed motor encoder and the encoder resolution. The factor used
for converting the position data from the drive-internal format into the
display format or vice versa is outside the allowable range, because either
• linear motor and rotary position scaling with motor reference, or
• rotary motor and linear position scaling with motor reference, or
• linear motor with modulo scaling has been selected; or
• the determined factor used for converting the position data from the
display format to the internal format, and vice versa, cannot be
represented.
Remedy:
Checking and correcting the relevant parameters, such as
• S-0-0076, Position data scaling type
• S-0-0077, Linear position data scaling factor