EasyManuals Logo

REXROTH ECODRIVE03 User Manual

REXROTH ECODRIVE03
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #82 background imageLoading...
Page #82 background image
5-10 Description of Diagnostic Messages B; C, D and A ECODRIVE03-SGP-03VRS
DOK-ECODR3-SGP-03VRS**-WA01-EN-P
C211 Invalid feedback data (->S-0-0022)
Invalid data has been encountered when the parameters stored in the
motor feedback were read, or an error has occurred when the data was
read.
Causes:
1. Motor feedback cable not connected or defective
2. Motor feedback defective
3. Drive controller defective
Remedy for:
1. Check motor feedback cable; connect both sides
2. Replace motor
3. Replace amplifier
See also the functional description "S-0-0128, C200 Communication
phase 4 transition check".
C212 Invalid amplifier data (->S-0-0022)
During drive initialization, the operating software accesses data from an
EEPROM in the drive controller. This error message is generated if the
attempt to read the data has failed.
Causes:
Defective hardware in the drive controller.
Remedy:
Replace drive controller.
See also the functional description "S-0-0128, C200 Communication
phase 4 transition check".
C213 Position data scaling error
Cause:
The scaling parameters for position data permit the position data display
format to be selected. The drive-internal position data format depends on
the employed motor encoder and the encoder resolution. The factor used
for converting the position data from the drive-internal format into the
display format or vice versa is outside the allowable range, because either
linear motor and rotary position scaling with motor reference, or
rotary motor and linear position scaling with motor reference, or
linear motor with modulo scaling has been selected; or
the determined factor used for converting the position data from the
display format to the internal format, and vice versa, cannot be
represented.
Remedy:
Checking and correcting the relevant parameters, such as
S-0-0076, Position data scaling type
S-0-0077, Linear position data scaling factor