20 June 2005 LASER UNIT
3-23
Replacement
Adjustment
3.10.2 LASER UNIT
WARNING
Turn off the main power switch and unplug the machine before attempting
this procedure. Laser beams can seriously damage your eyes.
1. Open the front door.
2. Raise the toner bottle holder handle [A].
3. Remove front door [B] (Pins x2)
4. Remove toner collection plate [C] ( x).
5. Remove inner cover [D] ( x 2, x 1)
6. While pressing in the top leaf on the left side, remove the shield glass cover [E].
The shield glass cover holds the shield glass firmly in place and prevents it
from accidental removal.
When re-attaching the shield glass cover, the top leaf lies on top of the
plastic form.
7. Shield glass [F]
B195R211.WMF
[A]
[B]
[C]
[D]
[E]
[F]