SERVICE CALL CONDITIONS 20 June 2005
4-4
SBU communication error 144 B
Immediately after power on, the
operation check done by the SIB for the
SBU failed because the SBU was not
operating normally.
Flat film or harness connectors
between the SBU and SIB are loose,
disconnected, or damaged
Replace SBU
Replace BICU
Copy Data Security Unit error 165 B
An error occurred when the machine
attempted to set the Copy Data
Security Unit SD card.
The Copy Data Security Unit card not
installed
The Copy Data Security Unit card is
installed, but it is not the correct type
for the machine.
Charge roller current leak 302 D
A charge roller current leak signal was
detected.
Charge roller damaged
High voltage supply board defective
PCU harness defective or
disconnected
Charge roller current correction error 304 D
The charge roller bias correction is
performed twice even if the maximum
charge roller bias (-2000V) is applied to
the roller.
ID sensor defective
F-Gate error: No laser writing signal 321 D
The laser writing signal (F-GATE) does
not go to LOW for more than 30
seconds after the copy paper reaches
the registration sensor.
BICU board defective
PCI harness between the controller
board and the BICU defective or
disconnected
Synchronization error 322 D
The synchronization signal was not
issued within 500 ms after the LD fired
while the polygon motor was turning at
the prescribed number of revolutions.
Laser synchronization board
connectors loose, disconnected, or
damaged
Laser synchronization board
defective
LD drive board defective
LD drive current too high 323 D
The LD drive board applies more than
100 mA to the LD.
LD unit defective (not enough power,
due to aging)
Poor connection between the LD unit
and the BICU board
BICU defective
LD unit home position error 1 327 D
The LD unit home position sensor does
not detect an on condition when the LD
unit moves to its home position.
HP sensor/harness defective
LD unit home position sensor
defective
LD positioning motor harness
defective
LD unit movement blocked because
of incorrect connector routing
LD unit home position error 2 328 D
The LD unit home position sensor does
not detect an off condition when the LD
unit moves from its home position.
HP sensor/harness defective
LD positioning/harness motor
defective
LD unit movement blocked because
of incorrect connector routing