20 June 2005 SERVICE CALL CONDITIONS
4-11
Trouble-
shooting
Communication command error
between BICU and ADF
612 D
The BICU sends a command to the ADF
main board that it cannot execute.
Abnormal operation performed by
software
Communication timeout error between
BICU and finisher or mailbox
620 D
The BICU cannot receive a response
within 100 ms after 3 attempts after
sending data to the finisher or mailbox.
Serial line connecting BICU and
finisher unstable
External noise
BICU board and finisher main board
connection defective or loose
Finisher main board defective
BICU board defective
Communication timeout error between
BICU and finisher or mailbox
621 D
A break (low) signal was received from
the finisher or the mailbox.
Serial line connecting BICU and
finisher unstable
External noise
Communication timeout error between
BICU and paper tray unit
623 D
The BICU cannot receive a response
within 100 ms after 3 attempts after
sending data to the paper tray unit.
Serial line connecting BICU and
paper tray unit unstable
External noise
BICU board and paper tray main
board connection defective or loose
Paper tray main board defective
BICU board defective
Communication break error between
BICU and paper tray unit
624 D
The BICU cannot communicate with the
paper tray unit normally as a result of
receiving a break signal.
Serial line connecting BICU and
paper tray unit unstable
External noise
BICU board and LCT main board
connection defective or loose
Optional paper feed unit interface
board defective
BICU board defective
Communication timeout error between
BICU and LCT
626 D
The BICU cannot receive a response
within 100 ms after 3 attempts after
sending data to the LCT.
Serial line connecting BICU and
LCT unit unstable
External noise
BICU board and LCT main board
connection defective or loose
LCT interface board defective
BICU board defective
Communication break error between
BICU and LCT
627 D
The BICU cannot communicate with the
LCT unit normally as a result of
receiving a break signal.
Serial line connecting BICU and
LCT unit unstable
External noise
BICU board and LCT main board
connection defective or loose
LCT interface board defective
BICU board defective
Communication failure with CSS (RSS) 630 D
The communication from the copier was
detected as abnormal at the CSS
center. This error occurs when the
acknowledge signal from the LADP does
not complete normally.
Occurred with a SC call, CC call,
Supply Management call, User call,
or CE call.
Timeout while no response from the
LADP, and signal on the RS-485
line between PI and LADP is
abnormal.