SERVICE CALL CONDITIONS 20 June 2005
4-16
Pattern Error Status Possible Cause
1-1-1
The shutter position switch does not
turn on within 1 second after the
transport motor starts to turn in reverse.
1-1-2
The shutter sensor does not deactivate
within 1 second after the transport
motor starts to turn in reverse.
1-1-3
Shutter
movement
The shutter position switch is off when
the shift tray safety switch is off.
Transport motor
defective
Shutter position
switch defective
Shift tray safety
switch defective
1-2-1
After the exit motor turns on, the exit
motor sensor does not send the proper
signal to the finisher board.
1-2-2
Exit motor
The exit motor sensor does not send
the clock signal to the finisher board for
certain period while the exit motor is on.
Exit motor
defective
Exit motor sensor
defective
1-3-1
The upper exit guide 2 switch does not
turn on within 1s after the guide plate
motor turns on.
1-3-2
The upper exit guide sensor does not
activate within 1s after the guide plate
motor turns on.
1-3-3
The upper exit guide 2 switch does not
turn on when the shift tray safety switch
is off.
1-3-4
Upper exit plate
movement
The guide plate motor sensor does not
send the clock signal to the finisher
board for certain period while the exit
motor is on.
Guide plate motor
defective
Upper exit guide 2
switch defective
Upper exit guide
sensor defective
Shift tray safety
switch defective
1-4-1
After the jogger motor turns on to move
the jogger fence from its home position,
the jogger HP sensor does not
deactivate within 2s.
1-4-2
Jogger motor
After the jogger motor turns on to return
the jogger fence to its home position,
the jogger HP sensor does not activate
within 2s.
Jogger motor
defective
Jogger HP sensor
defective
1-5-1
After the stapler motor turns on to move
the stapler unit from its home position,
the stapler unit HP sensor does not
deactivate within 4s.
1-5-2
Stapler motor
After the stapler motor turns on to
return the stapler unit to its home
position, the stapler unit HP sensor
does not activate within 4s.
Stapler motor
defective
Stapler unit HP
sensor defective
1-6-1
The staple hammer HP sensor does not
deactivate within 0.5s after the staple
hammer motor turns on.
1-6-2
Staple hammer
motor
The staple hammer HP sensor does not
activate within 0.5s after the staple
hammer motor turns on.
Staple hammer
motor defective
Staple hammer HP
sensor defective