SERVICE PROGRAM MODE TABLES 20 June 2005
5-38
5212 Page Numbering
5212 3 Duplex Printout Left/Right Position Horizontally positions the page numbers
printed on both sides during duplexing.
[–10~+10/1 mm]
0 is center, minus is left, + is right.
5212 4 Duplex Printout High/Low Position Vertically positions the page numbers printed
on both sides during duplexing.
[–10~+10/1 mm]
0 is center, minus is down, + is up.
Bypass Size Error 5179*
This SP determines whether a paper size error prompt appears when the machine
detects the wrong paper size for the job and jams during feed from the bypass tray.
[0~1/0/1]
0: Off
1: On
Set Time DFU 5302
Sets the time clock for the local time. This setting is done at the factory before
delivery. The setting is GMT expressed in minutes.
[–1440~1440/1 min.]
JA: +540 (Tokyo)
NA: -300 (NY)
EU: +6- (Paris)
CH: +480 (Peking)
TW: +480 (Taipei)
AS: +480 (Hong Kong)
Auto Off Function Release Setting 5305
This SP prevents the user from easily disabling the auto off timer. This is done to
conform with international Energy Star standards that specifically state that the user
shall not be able to easily switch off the auto off feature.
0: On (Auto Off cannot be released
1: Off (Auto Off can be released)