20 June 2005 SERVICE PROGRAM MODE TABLES
5-41
Service
Tables
5507
Supply Alarm
5507 1 Paper Supply Alarm
(0:Off 1:On)
Switches the control call on/off for the paper supply.
DFU
0: Off, 1: On
0: No alarm.
1: Sets the alarm to sound for the specified number
transfer sheets for each paper size (A3, A4, B4, B5,
DLT, LG, LT, HLT)
5507 2 Staple Supply Alarm
(0:Off 1:On)
Switches the control call on/off for the stapler installed in
the finisher. DFU
0: Off, 1: On
0: No alarm
1: Alarm goes off for every 1K of staples used.
5507 3 Toner Supply Alarm
(0:Off 1:On)
Switches the control call on/off for the toner end. DFU
0: Off, 1: On
If you select “1” the alarm will sound when the copier
detects toner end.
5507 128* Others
5507 132* Interval: A3
5507 133* Interval: A4
5507 134* Interval: A5
5507 141* Interval: B4
5507 142* Interval: B5
5507 160* Interval: DLT
5507 164* Interval: LG
5507 166* Interval: LT
5507 172* Interval: HLT
The “Paper Supply Call Level: nn” SPs specify the paper
control call interval for the referenced paper sizes. DFU
[00250 ~ 10000 / 1000 / 1 Step]