SERVICE PROGRAM MODE TABLES 20 June 2005
5-80
7801 ROM No./Firmware
Version
Displays the ROM number and firmware version
numbers.
7803* PM Counter Display Displays the PM counter since the last PM.
7804 PM Counter Reset
Resets the PM counter. To reset, press .
SC/Jam Counter Reset
Resets the SC and jam counters. To reset, press .
7807
This SP does not reset the jam history counters: SP7-507, SP7-508.
7808 Counter Reset Resets all counters except SP7-003-***, SP7-006-***.
To reset, press .
Access Code Clear
Clears the access code. To clear, press .
7810
Use to clear the access code if the customer forgets the code. After clearing the
code is reset for Null and the password entry display does not open.
7811 Original Count Clear Clears the original total display, displayed with SP7-
002-***. To clear, press .
7816 Print Counter Reset by Tray
7816 1 Bypass
7816 2 Tray 1
7816 3 Tray 2
7816 4 Tray 3
7816 5 Tray 4
7816 6 LCT
Resets the total copy count by paper tray. To reset, press
.
Use these SP modes when replacing the pick-up, feed,
and separation rollers.
7825 Total Counter Reset No longer used. (Has no effect)
MF Error Counter Japan Only 7826
Displays the number of counts requested of the card/key counter.
7826 1 Error Total A request for the count total failed at power on. This error will
occur if the device is installed but disconnected.
7826 2 Error Staple The request for a staple count failed at power on. This error will
occur if the device is installed but disconnected.
MF Error Counter Clear 7827
Press Execute to reset to 0 the values of SP7826. Japan Only
Self-Diagnosis Result Display Opens the “Self-Diagnose Result Display” 7832
Execute to open the “Self-Diagnose Result Display” to view details about errors. Use
the keys on in the display on the touch-panel to scroll through all the information. If no
errors have occurred, you will see the “No Error” notation.