20 June 2005 SCANNER ACCESSIBILITY OPTION (B815)
1-83
Installation
3. Remove:
[A]: BICU shield plate ( x3)
[B]: IPU shield plate ( x1)
NOTE: A support on the BICU shield
plate overlaps a support of the IPU
shield below. One screw [C] fastens
both.
4. Remove the harness clamps from the
old IPU shield plate and attach them to
the new plate (x2).
5. Reattach:
New IPU shield plate ( x1)
BICU shield plate ( x3).
Controller box ( x5, x1)
Reattach rear lower cover ( x4)
Reattach the corner plate ( x2)
ARDF
Important:
This completes the pre-installation procedure for this option.
The mainframe can now be moved to the work site.
B815I110.WMF
B815I111.WMF
[A]
[B]
[C]