9 March 2004 ERROR CODES
2-1
Trouble-
shooting
2. TROUBLESHOOTING
2.1 ERROR CODES
When a communication error occurs, retry to establish the communication. If the
error recurs, see the tables below and solve the problem. Note that some error
codes are seen only in the printed reports.
Code Meaning Suggested Cause/Action
0-00 DIS/NSF not detected within
40 s of Start being pressed
Check the line connection.
The machine at the other end may be
incompatible.
Replace the FCU.
Check for DIS/NSF with an oscilloscope.
If the rx signal is weak, there may be a bad line.
0-01 DCN received unexpectedly
The other party is out of paper or has a jammed
printer.
The other party pressed Stop during
communication.
0-03 Incompatible modem at the
other end
The other terminal is incompatible.
0-04 CFR or FTT not received
after modem training
Check the line connection.
Try changing the tx level and/or cable equalizer
settings.
Replace the FCU.
The other terminal may be faulty; try sending to
another machine.
If the rx signal is weak or defective, there may be
a bad line.
Cross reference
Tx level - NCU Parameter 01 (PSTN)
Cable equalizer - G3 Switch 07 (PSTN)
Dedicated Tx parameters - Section 4
0-05 Unsuccessful after modem
training at 2400 bps
Check the line connection.
Try adjusting the tx level and/or cable equalizer.
Replace the FCU.
Check for line problems.
Cross reference
See error code 0-04.
0-06 The other terminal did not
reply to DCS
Check the line connection.
Try adjusting the tx level and/or cable equalizer
settings.
Replace the FCU.
The other end may be defective or incompatible;
try sending to another machine.
Check for line problems.
Cross reference
See error code 0-04.