9 March 2004 ENERGY SAVER MODES OF BASIC MACHINES
6-15
Detailed
Descriptions
6.9 ENERGY SAVER MODES OF BASIC MACHINES
This section (6.9) illustrates the energy saver modes of the basic machine (the
machine without the controller box). For the energy saver modes of the other
models (the machines with the controller box), see section 6.10.
Overview
The machine has two energy-saver modes: the Low Power Mode and the Night/Off
Mode. The table lists the status of several components.
Operation panel Engine Exhaust fan
Operating Mode* On On On
Low Power Mode Off On Off
Night/Off Mode Off Off** Off
* The “Operating Mode” here refers to all the modes (and status) other than the Low Power Mode
and Night/Off Mode. Actual power consumption (during the Operating Mode) depends on job
status and environmental conditions.
** The SRAM is alive and backs up the engine controller.
B130D931.WMF
Power
consumption
Operating Mode
Low Power Mode
Night/Off Mode
Time
Energy Saver Timer
Auto Off Timer
t