9 March 2004 PM TABLES
2-1
Preventive
Maintenance
2. PREVENTIVE MAINTENANCE
2.1 PM TABLES
Reset the PM counter (SP7-804-001) after your maintenance work (☛ 2.2).
Key: AN: As necessary C: Clean R: Replace I: Inspect
Every 45k Every 90k AN NOTE
OPTICS
Reflector C C Optics cloth
1st mirror C C Optics cloth
2nd mirror C C Optics cloth
3rd mirror C C Optics cloth
Platen cover C C Dry cloth
Exposure glass C C Dry cloth
Toner shield glass C C Dry cloth
DRUM AREA
PCU R Clean toner-bottle holder.
Transfer roller R
Discharge plate R
PAPER FEED
Paper feed roller R C Water or alcohol.
Friction pad R C Dry cloth
Bottom-plate pad C C Water or alcohol.
Registration roller C C Water or alcohol.
FUSING UNIT
Hot roller R
Pressure roller R
Hot roller bearings R
Pressure-roller
bushings
I
Inlet guide C
Outlet guide C
Hot roller stripper
pawls
R
Thermistor C