EasyManua.ls Logo

Ricoh Aficio 1515 - Bit Switches; System Switches

Ricoh Aficio 1515
329 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BIT SWITCHES 9 March 2004
3-6
3.2 BIT SWITCHES
!
CAUTION
Do not change the settings marked with the key "Not used." Changing
these settings may cause malfunctions and/or may violate local
regulations.
NOTE:
For the default settings of the bit switches, see the System Parameter List
( SP6-101-001).
3.2.1 SYSTEM SWITCHES
System Switch 00 SP No. 1-101-001
No FUNCTION COMMENTS
0
Dedicated transmission
parameter programming
0: Disabled 1: Enabled
Set this bit to 1 before changing any dedicated
transmission parameters.
Reset this bit to 0 after programming dedicated
transmission parameters.
1
Not used Do not change the setting.
Technical data printout on the
Journal
0: Disabled
1: Enabled
1: Instead of the personal name, the following data
are listed on the Journal for each G3
communication.
2
e.g.
0000 32V34 288/264 L0100 03 04
(1) (2)(3) (4) (5) (6) (7) (8)
(1): EQM value (Line quality data). A larger number means more errors.
(2):
Symbol rate (V.34 only)
(3): Final modem type used
(4): Starting data rate (for example, 288 means 28.8 kbps)
(5):
Final data rate
(6): Rx revel (refer to the note after this table for how to read the rx level)
(7): Total number of error lines that occurred during non-ECM reception.
(8):
Total number of burst error lines that occurred during non-ECM reception.
Note:
EQM and rx level are fixed at “FFFF” in tx mode.
The seventh and eighth numbers are fixed at “00” for transmission records and
ECM reception records.