Bit Switches
D432/D433 62 SM
1: Disabled
2-3
Not used
Do not change these settings.
4-5
Interval for preventing the
machine from entering Energy
Saver mode if there is a
pending transmission file.
Bit 5: 0, Bit 4: 0
1 min
Bit 5: 0, Bit 4: 1
30 min1
Bit 5: 1, Bit 4: 0
1 hour
Bit 5: 1, Bit 4: 1
24 hours
If there is a file waiting for transmission, the
machine does not go to Energy Saver mode
during the selected period.
After transmitting the file, if there is no file waiting
for transmission, the machine goes to the Energy
Saver mode.
6-7
Not used
Do not change
System Switch 16 [SP No. 1-101-023]
No FUNCTION COMMENTS
0-7
Not used
Do not change these settings.
System Switch 17 - Not used (do not change these settings)
System Switch 18 - Not used (do not change these settings)
System Switch 19 [SP No. 1-101-026]
No FUNCTION COMMENTS
0-6
Not used
Do not change the settings.
7
Special Original mode
0: Disabled
1: Enabled
1: If the customer frequently wishes to transmit a
form or letterhead which has a colored or printed
background, change this bit to “1”. “Original 1” and