006
Counter K ENG [0 to 999999999 / 0 / 1mm/step]
Rotation counter (Bk) to determine if development roller reverse is required or not.
007
Counter Cl ENG [0 to 999999999 / 0 / 1mm/step]
Rotation counter (Color) to determine if development roller reverse is required or not.
2915 [GainAdj:BkOpcDevM]
001 Standard Speed *ENG
[0 to 65535 / 0 / 10/step]
002 Low Speed *ENG
2916 [GainAdj:ColorOpcDevM]
001 Standard Speed *ENG [0 or 1 / 0 / 1/step]
002 Low Speed *ENG [0 or 1 / 1 / 1/step]
2930
[Transfer:Bias Limiter]
Adjusts the threshold between high resistance (division 1) and low resistance (division 2)
at the paper transfer roller.
001 Bias *ENG [0 to 7000 / 6000 / 10-V/step]
2931
[-]
Sets the waiting time for job end cleaning in normal speed.
001 - *ENG
[-2000 to 2000 / 0 / 1msec/step]
003 - *ENG
004 - *ENG
006 - *ENG
2941 [Dev.Bias DownMode]
001 T5:Bk:std *ENG [-140 to 140 / -10 / 10msec/step]
002 T7:FC:std *ENG [-140 to 140 / -20 / 10msec/step]
Main SP Tables-2