System Service Mode
SM Appendix 8-213 M065/M066
Appendix:
SP Mode
Tables
029
Correction Coeff. 2: Interrupt:
FC
*ENG
[0 to 1 / 1 / 0.01/step]
030
Max. Number Correction
Threshold
*ENG
[0 to 99 / 5 / 1/step]
031
Max. Number Correction
Counter
*ENG
[0 to 255 / 0 / 1/step]
3512
[Image Adj.: Interval]
Adjusts the timing for execution of process control and line position adjustment
during printing.
001 During Job *ENG
[0 to 100 / 10 / 1 page/step]
002 During Stand-by *ENG
[0 to 100 / 10 / 1 minute/step]
3513
[PCU Motor Stop Time: Bk]
Displays the last time that the PCU motors stopped.
These are used for process control execution timing.
001 Year *ENG
[0 to 99 / 0 / 1/step]
002 Month *ENG
[1 to 12 / 1 / 1/step]
003 Day *ENG
[1 to 31 / 1 / 1/step]
004 Hour *ENG
[0 to 23 / 0 / 1/step]
005 Minute *ENG
[0 to 59 / 0 / 1/step]