Service Call 490-491
SM 6-21 D255/D256/M281/M282
Troubleshooting
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC491-01 D Drum Unit Type Mismatch Error
Cannot communicate with the EEPROM of the drum PCB
normally.
An incompatible drum unit is installed.
Connector defective or disconnected
Drum PCB defective
Connect-Left PCB defective
IOB defective
Connector defective or disconnected
Reconnect the following connectors. Then perform a
conduction inspection. If there is no conduction, replace the
connector.
Drum Unit Drum Connection PCB connector
Drum Connection PCBConnect-Left PCB connector
Connect-Left PCBIOB connector
Drum PCB defective
Replace the drum PCB.
Connect-Left PCB defective
Replace the Connect-Left PCB.
IOB defective
Replace the IOB.