Service Call 622-691
D255/D256/M281/M282 6-56 SM
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC672-11
D Controller start up error
After the machine was powered on, communication between the
controller and the operation panel was not established, or
communication with controller was interrupted after a normal
startup.
Controller stalled
Board installed incorrectly
Controller board defective
Operation panel connector loose, broken, or defective
Controller late
1. Turn the main power OFF/ON.
2. Check the connection of the operation panel.
3. Check the connection of the controller board.
4. Replace the controller board.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC672-12 D Controller start up error
Communication with controller was interrupted after a normal
startup.
Controller stalled
Board installed incorrectly
Controller board defective
Operation panel connector loose, broken, or defective
Controller late
1. Turn the main power OFF/ON.
2. Check the connection of the operation panel.
3. Check the connection of the controller board.
4. Replace the controller board.