EasyManua.ls Logo

Ricoh M281 Series - Page 959

Ricoh M281 Series
1003 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NCU Parameters
SM 125 D255/D256 FAX OPTION
D255/D256
FAX OPTION
Sweden 10 0A Korea 28 1C
Switzerland 11 0B Brazil 29 1D
# RAM
Addr.
Function Unit Remarks
01 6805B4 PSTN: Tx level from the modem -N 3 dBm SP2-103-002
02 680572 Acceptable ringing signal
frequency: range 1, upper limit
1000/ N
(Hz).
SP2-103-003
03 680573 Acceptable ringing signal
frequency: range 1, lower limit
SP2-103-004
04 680574 Acceptable ringing signal
frequency: range 2, upper limit
SP2-103-005
05 680575 Acceptable ringing signal
frequency: range 2, lower limit
SP2-103-006
06 680576 Number of rings until a call is
detected 1
SP2-103-007
The setting must not
be zero.
07 680577 Minimum required length of the first
ring
20 ms
See Note B.
SP2-103-008
08 680578 Minimum required length of the
second and subsequent rings
20 ms
SP2-103-009
09 680579 Ringing signal detection reset time
(LOW)
20 ms
SP2-103-010
10 68057A Ringing signal detection reset time
(HIGH)
SP2-103-011
11 68054A Time between opening or closing
the DO relay and opening the
OHDI relay
1 ms
See Notes A, D and
E. SP2-103-012
12 68054B Break time for pulse dialing
1 ms
See Note A.
SP2-103-013