5. Check that the blue marks [F] of the wire overlap, and secure it temporarily with Teflon
tape, etc.
6. Set the pulley on the drive shaft [G] (tighten the screw temporarily).
7. Set the ball end of the wire in the following order.
1. Left frame pulley (outside) [H]
2. 2nd scanner carriage (outside) [I]
3. Left frame slit [J]
8. Set the ring end of the wire in the following order.
1. Right frame pulley (outside) [K]
1. 2nd scanner carriage (inside) [L]
2. Scanner retaining bracket [M]
(Tighten the screw of the scanner retaining bracket temporarily)
9. Remove the tape which temporarily held the wire in Step 5.
10. Attach the spring.