Loading...
SP name Value NA EU CHN TWN Asia
SP5101-008
(Timer Set: -)
Min. 0
(Disable)
0
(Disable)
0
(Disable)
0
(Disable)
0
(Disable)
Default 0
(Disable)
0
(Disable)
0
(Disable)
0
(Disable)
0
(Disable)
Max. 1 (Enable) 1 (Enable) 1 (Enable) 1 (Enable) 1
(Enable)
Step - - - - -
SP5101-104
(Timer Set: Low
Power Set)
Min. 0
(Disable)
0
(Disable)
0
(Disable)
0
(Disable)
0
(Disable)
Default 0
(Disable)
0
(Disable)
0
(Disable)
0
(Disable)
0
(Disable)
Max. 1 (Enable) 1 (Enable) 1 (Enable) 1 (Enable) 1
(Enable)
Step - - - - -
Timer Settings
The user can set these timers with User Tools (System settings > Timer setting)
Energy saver timer (1-30 min for NA and EU/1-240 min for others): Low Power Mode. Default
setting: 1 min.
Auto off timer (1-60 min for NA and EU/1-240 min for others): Off/Sleep Mode. Default setting:
1 min.
Normally, Energy Saver timer < Auto Off timer. But, for example, if Auto Off timer < or = Energy Saver
timer, the machine goes immediately to Off mode when the Auto Off timer expires. It skips the Energy
Saver mode.
Example
Low power: 15 min.
Auto Off: 1 min.
The machine goes to Off mode after 1 minute. Low Power mode is not used.