The characteristic values attached to the service part must be entered before replacement. It is
recommended that in case Process control/MUSIC after replacement is not completed
successfully, take a note of values of SP3-333,SP3-334,SP3-335.
1. Note the characteristic values that are listed on the bar code label.
TM/P Sensor (front): F, TM/P Sensor (center): C, TM/P Sensor (rear): R, be careful.
2. Turn on the main power switch, and then go into the SP mode.
3. Input the characteristic values.
Input data for TM/P Sensor: F into SP3-333. Input data for TM/P sensor: C into SP3-334. Input
data for TM/P sensor: R into SP3-335.
SP No. Classification 1 Classification 2 Value
3-333-00
1
ID.Sens TestVal:F K2: Check TM/P sensor: F, value of [1]
3-333-00
2
ID.Sens TestVal:F Diffuse Corr TM/P sensor: F, value of [2]
3-333-00
3
ID.Sens TestVal:F
Vct_reg
Check:Slope
TM/P sensor: F, value of [3]
3-333-00
4
ID.Sens TestVal:F
Vct_reg
Check:Xint
TM/P sensor: F, value of [4]
3-333-00
5
ID.Sens TestVal:F
Vct_dif
Check:Slope
TM/P sensor: F, value of [5]
3-333-00
6
ID.Sens TestVal:F Vct_dif Check:Xint TM/P sensor: F, value of [6]
3-334-00
1
ID.Sens TestVal:C K2: Check TM/P sensor: C, value of [1]