A: 4.2±2mm
B: 2±1mm
SP No. SP Name Range
SP6-006-001 Side-to-Side Regist: Front ±3.0mm
SP6-006-003 Side-to-Side Regist: Rear ±5.0mm
SP6-006-005 Leading Edge Registration ±3.0mm
SP6-006-006 Buckle: Duplex Rear ±2.5mm
SP6-006-007 Rear Edge Erase ±10.0mm
<Sub scan magnification adjustment>
1. Set the same test chart as the one used in the Registration adjustment in the ADF. Select a feed tray
that has A3 paper, and start copying.
2. Check whether the Sub scan magnification is within the standard range. If not, adjust it with
SP6-017-001(ADF Magnification Adj.).
Standard (Magnification tolerance)
* Same Size: Sub scan: ±5.0%
* Reduction: Sub scan: ±1.00%
* Enlargement: Sub scan: ±1.00%