Loading...
SC No. Level Error Name/Error Condition/Major Cause/Solution
-02 D Lamp Error (LED illumination adjustment)
LED error was detected.
LED defective
IDB (LED driver) defective
Power/signal harness defective
1. Turn the power off/on.
2. Perform the following operations:
Reconnect the power/signal harness.
3. Replace the following parts:
Replace the LED board.
Replace the IDB board or SIO board.
Replace the power/signal harness.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC102-00 D LED Illumination Adjustment Error
The white level peak reached the prescribed threshold when the white
plate was scanned after a specified number of adjustments.
LED defective
IDB (LED driver) defective
SBU defective
IPU defective
Power/signal harness defective
1. Turn the power off/on.
2. Reconnect the power/signal harness.
3. Replace the following parts:
Replace the LED board.
Replace the SBU board.
Replace the IDB board or SIO board.
Replace the IPU board.
Replace the power/signal harness.
Service Call 101-195