SC No. Level Error Name/Error Condition/Major Cause/Solution
SC121-00 D Scanner Home Position Error 2
The scanner home position sensor does not go ON.
Details:
Error detection timing
During homing
During an automatic adjustment
During a scan from the ADF or exposure glass.
Scanner motor driver defective
Scanner motor defective
Scanner HP sensor defective
Harness defective
Timing belt, pulley, wire, or carriage not installed correctly
Replace the following parts:
Replace the home position sensor
Replace the scanner motor
Replace the harness.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC141-00 D Black level detection error
The black level cannot be adjusted within the target during auto gain
control.
SBU defective
IPU defective
Power/signal harness defective
1. Turn the power off/on.
2. Reconnect the power/signal harness.
3. Replace the following parts:
Replace the SBU board.
Replace the IPU board.
Replace the power/signal harness.
Service Call 101-195