SC No. Level Error Name/Error Condition/Major Cause/Solution
SC204-00 D Polygon Motor: XSCRDY Signal Error
During polygon motor rotation, the XSCRDY signal was inactive (H) for
longer than one rotation of the polygon.
The interface harness to the polygon motor driver damaged or not
connected correctly.
Polygon motor or polygon motor driver defective
Turn the power off/on
Replace the LSU or polygon motor
Replace the polygon harness
Replace the IPU board
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC220-01 D Leading Edge: LD1 synchronization detection error: Bk
SC220-04 D Leading Edge: LD1 synchronization detection error: Ye
The leading edge LD0 synchronization detection signal of the
corresponding color was not output within T1 sec. while the polygon
mirror motor was operating at normal speed.
The interface harness to the synchronization detection unit damaged
or not connected correctly.
Synchronization detection board defective
Beam does not enter photo detector.
Abnormality around GAVD
IDB (LED driver) defective
LDB defective
BCU defective
Turn the power off/on
Replace the LSU or polygon motor
Replace the polygon harness
Replace the IPU board