SC No. Level Error Name/Error Condition/Major Cause/Solution
SC285-00 C MUSIC error
The results of MUSIC pattern reading failed 4 times.
(even if mode e (real time MUSIC) fails, the error count is not
incremented (+1))
TM sensor defective
ITB defective
PCU defective
LD unit defective
MUSIC pattern density thin
ITB reset
PCU reset
Toner replenishment
Replace the TM (ID) sensor
Replace the ITB
Replace the PCU
Replace the LD unit