SC No. Level Error Name/Error Condition/Major Cause/Solution
SC505-41 B Side LCIT Limit Detection Error
Upper limit detection error (during descent)
During tray initialization (upper limit detection/lower limit not
detected), the tray base plate is lowered to check the tray base
plate position, but the limit sensor is detected although a
predetermined time elapsed.
Upper limit detection error (during ascent)
During tray initialization (upper limit not detected /lower limit
detection), the tray base plate is raised to check the tray base plate
position, but the limit sensor is not detected although a
predetermined time elapsed.
*If an error occurs for 3 times consecutively: the side LCIT transmits
a "5th paper feed tray upper limit detection error" to the main
machine.
Up to 2 times consecutively, the side LCIT transmits a "tray set fault"
to the main machine.
Service Call 501-584
493

Table of Contents